By the Phanton Mechanical team · TX Mechanical TACLA124868E · TX Electrical TECL39666

North Texas winters are short, but they do not ease in. The cold tends to arrive all at once, and when it does, every heating system in the Metroplex starts at the same time — the February 2021 winter storm showed how quickly that becomes a grid emergency. The cheapest time to find a dirty burner, a weak igniter, or a dead carbon monoxide detector is a mild November week, not the first hard freeze. Here is the checklist, split into what you can do this weekend and what needs a licensed technician.

What You Can Check Yourself

  • The filter. ENERGY STAR recommends inspecting it once a month and cleaning or changing it as needed. A clogged filter starves the furnace of air; an overheating furnace shuts itself off on its high-limit switch, restarts, and shuts off again.
  • The thermostat. Switch it to Heat, set it a few degrees above room temperature, and confirm warm air within a few minutes. Replace the batteries if it uses them.
  • Carbon monoxide detectors. The CDC recommends battery-operated or battery-backup CO detectors near every sleeping area, with batteries checked when the clocks change. The clocks changed on November 1 — if you skipped it, test them this week.
  • The outdoor unit, if you have a heat pump. Clear leaves and debris from around it, and never cover a heat pump in winter — it is running.
  • The vents. Open the supply registers and keep furniture and rugs off the returns.

Gas Furnaces: The Inspection That Matters

Gas heat is where a professional check earns its fee. ENERGY STAR’s maintenance checklist has the contractor check all gas connections, gas pressure, burner combustion, and the heat exchanger, and the CDC recommends having your heating system, water heater, and other fuel-burning appliances serviced by a qualified technician every year. The heat exchanger is the part that keeps combustion gases out of the air you breathe; a cracked one does not fix itself, and it is not something you can see from the furnace door.

The stakes are real: per the CDC, more than 400 Americans die each year from unintentional carbon monoxide poisoning not linked to fires, and more than 100,000 visit an emergency department. A faint burning-dust smell the first time the heat runs each season is normal and fades quickly. Call if the smell lingers, if the furnace starts and shuts off repeatedly, or if the igniter clicks without lighting. If a CO alarm sounds, get everyone outside first, then call.

Heat Pumps: Know What Normal Looks Like

A heat pump in winter does a few things that look like problems and are not. On cold, damp mornings the outdoor coil frosts over and the system runs a defrost cycle: the outdoor fan stops, you may hear a whoosh, and the unit can give off steam for a few minutes. That is normal. So is backup (auxiliary) heat coming on during defrost or on the coldest mornings.

What is not normal: ice that builds up on the coil and stays, a unit that seems to defrost constantly, or auxiliary heat running all day on a mild day. Those point to a control, refrigerant, or airflow problem — and they show up on the electric bill. Leave “Emergency Heat” off unless the outdoor unit has actually failed: it shuts the heat pump off and heats the house on backup heat alone.

Thermostat Settings That Actually Save

The U.S. Department of Energy says you can save as much as 10% a year on heating and cooling by turning the thermostat back 7°–10°F for 8 hours a day from its normal setting — overnight, or while the house is empty. Heat pumps are the exception: DOE notes that programmable thermostats have generally not been recommended for heat pump systems, because a deep setback can make the system recover on expensive auxiliary heat. With a heat pump, use a thermostat designed for heat pumps or keep setbacks small. When we install a smart thermostat on a heat pump, we configure the auxiliary-heat staging so the savings are real.

If the Power Goes Out

  • Never run a generator inside the house or the garage, even with the door open. The CDC says to run it outdoors, more than 20 feet from windows, doors, and vents.
  • Never heat the house with a gas oven, range, or outdoor grill.
  • Space heaters: keep them clear of anything that can burn, plug them directly into a wall outlet rather than an extension cord, and turn them off when you leave the room or go to sleep.
  • When power returns and the heat will not restart, check the breaker once. If it trips again, leave it off and call — repeated tripping is a fault, not a reset problem.

DIY or Call a Pro

Winter HVAC checklist: homeowner tasks versus licensed-technician tasks
TaskWhoWhen
Inspect and change the air filterYouInspect monthly; change as needed
Test the thermostat in Heat modeYouBefore the first cold front
Test CO detectors and replace batteriesYouWhen the clocks change
Clear debris around the outdoor unitYouAfter storms and leaf fall
Gas connections, gas pressure, burner combustion, heat exchangerLicensed technicianEvery year, in the fall
Heat pump defrost controls, refrigerant charge, auxiliary heatLicensed technicianEvery year
Electrical connections and safety controlsLicensed technicianEvery year

If your system has not had a heating check this year, it is not too late — and it is a lot easier to get on the schedule in November than on the first night below freezing.

Sources: ENERGY STAR — Maintenance Checklist · CDC — Carbon Monoxide Poisoning Basics · U.S. DOE — Home Upgrades: Thermostats

Frequently Asked Questions

Quick Answers.

Why is my heat pump blowing steam?

Almost certainly a defrost cycle. In cold, damp weather the outdoor coil frosts over, and the heat pump briefly runs in reverse to melt it — the fan stops and the melting frost can come off as steam. A few minutes of that is normal. Ice that builds up and stays is not; call for service.

When should I use Emergency Heat?

Only when the outdoor unit has failed or been damaged. Emergency Heat turns the heat pump off and heats with backup heat alone, which costs considerably more to run. If you need it, call — it means the heat pump needs repair.

How often should a furnace be inspected?

Every year. ENERGY STAR recommends checking the heating system in the fall, and the CDC recommends having your heating system, water heater, and other fuel-burning appliances serviced annually by a qualified technician.

Where should carbon monoxide detectors go?

The CDC recommends battery-operated or battery-backup detectors near every sleeping area, with batteries checked when you change the clocks and the detectors replaced on the manufacturer’s schedule.

Is a burning smell normal when I first turn on the heat?

A faint dusty smell the first time the furnace runs each season is normal — it is dust burning off and it fades quickly. A smell that lingers or smells electrical is not; turn the system off and call. If you smell gas, leave the house and call your gas utility from outside.

Should I cover my outdoor unit in winter?

Never cover a heat pump — it runs all winter and needs airflow. For an air-conditioner-only condenser, follow the manufacturer’s guidance; a cover that traps moisture can do more harm than good.