Furnace Not Heating? A Furnace Repair Guide for Arlington Homes
A furnace that runs without heating the house usually comes down to a short list: a clogged filter tripping the high-limit switch, a dirty flame sensor, a failed ignitor, a vent or pressure-switch problem, or a thermostat that is not actually calling for heat. A few of those you can rule out in five minutes. The rest need a licensed technician.
Timing matters in North Texas. The National Weather Service’s Fort Worth office lists November 22 as the average date of the first freeze at DFW and March 12 as the average last freeze, so for the better part of four months a furnace that quits is not a wait-until-next-week repair. This guide covers what each symptom means, what you can safely check, and where furnace repair stops being a homeowner job.
How a Gas Furnace Starts, Step by Step
Every heating cycle runs the same sequence, and knowing it tells you where yours is stopping. The thermostat calls for heat. The control board starts a small draft fan called the inducer, and a pressure switch confirms the vent is actually pulling. The ignitor glows or sparks, the gas valve opens, and the burners light. A flame sensor then has a few seconds to prove there is a flame; if it cannot, the board closes the gas valve. Once the heat exchanger warms up, the main blower starts and pushes warm air through the ducts.
If any step is not proven, the furnace stops there on purpose. Most control boards retry a few times and then lock out for a while, which is why a failing furnace often seems to start, quit, and start again. Many also blink a fault code on a small light you can see through a window in the furnace door. Note the pattern before you switch the power off, because cutting power often clears it — and that code is the first thing a technician will ask about.
Furnace Symptoms and What They Usually Mean
| What you notice | Usual cause | Who fixes it |
|---|---|---|
| Blower runs, air is cold | Thermostat fan set to On instead of Auto, burners that are not lighting, or a high-limit switch tripped by a clogged filter | Check the fan setting and the filter; a technician for the rest |
| Burners light, then go out within seconds | Dirty or failed flame sensor: the board cannot prove flame, so it closes the gas valve | Licensed technician |
| Clicking or a glow, but no flame | Failed ignitor, or a gas supply or gas valve problem | Licensed technician |
| Small fan starts, then nothing | Pressure switch not closing: a blocked vent or intake, a failing inducer motor, or a clogged condensate drain on a high-efficiency furnace | Licensed technician |
| Heat runs a few minutes, shuts off, restarts | Furnace overheating and tripping the high-limit switch: clogged filter, closed registers, or a failing blower | Change the filter and open the registers; a technician if it continues |
| Burners run but the blower never starts | Blower motor, its capacitor, or the control board | Licensed technician |
| Nothing happens at all | No power or no call for heat: the furnace switch, the breaker, the door switch, or the thermostat | Check the switch and the breaker once; then a technician |
| Heat pump runs constantly and the house stays cool | Low refrigerant, a defrost-control fault, a reversing-valve problem, or backup heat that is not coming on | Licensed technician |
Treat the table as a starting point, not a diagnosis. Two different failures can produce the same symptom — burners that light and drop out can be a dirty flame sensor or a gas-pressure problem — and the fix for one does nothing for the other. That is the reason to test before replacing parts.
What You Can Safely Check First
Four checks cost nothing and are worth doing before anyone drives out. Set the thermostat to Heat, raise the setpoint a few degrees above room temperature, and set the fan to Auto rather than On. Look at the filter: a clogged filter can overheat a furnace until its safety limit shuts it down, and ENERGY STAR notes that a dirty filter can increase energy costs and damage your equipment, leading to early failure. Find the furnace power switch — it looks like a light switch near the unit — and make sure it is on. Then check the breaker and reset it once. If it trips again, leave it off.
Stop there. Do not bypass a safety switch, tape down a door switch, or try to light a burner by hand; those parts exist to shut the furnace down when something is wrong. Our winter HVAC checklist covers the rest of what a homeowner should handle before and during the season.
When to Leave the House Instead
A gas smell is not a furnace-repair call. Atmos Energy, the natural gas utility that serves Arlington, says that if you suspect a leak you should leave the area immediately and, from a safe distance, call 911 and its 24-hour emergency number, 866.322.8667. Our own advice for the way out: do not touch the thermostat, light switches, or the furnace. Atmos also warns against relying on smell alone — listen and look for signs of a leak too — and says it will send a trained technician to investigate at no cost. Once the utility has made the line safe, we diagnose and repair the equipment.
Carbon monoxide is the other hard stop. If a CO alarm sounds, get everyone outside and call 911. The CDC lists the most common symptoms of CO poisoning as headache, dizziness, weakness, upset stomach, vomiting, chest pain, and confusion, and notes that they are often described as flu-like. In our view, several people in the house feeling that way while the heat is running is a reason to get out, not to wait. A yellow or flickering burner flame, or a burning smell that lingers, means shut the furnace off and call.
Heat Pumps Fail Differently
A heat pump has no burners, so none of the ignition failures apply. Its supply air is warm rather than hot even when everything is working, so judge it by whether the house reaches the setpoint. When it does not, the usual causes are low refrigerant, a defrost-control fault, a reversing valve stuck between heating and cooling, or a failed outdoor fan motor. Ice that builds on the outdoor coil and stays there is a defrost problem, not weather.
The expensive failure is the quiet one: the heat pump stops doing its share and the electric backup strips carry the house. You stay warm, and the bill shows it. The U.S. Department of Energy says today’s heat pump can reduce electricity use for heating by approximately 65% compared with electric resistance heating, and backup strips are electric resistance heating. If the auxiliary-heat indicator stays on through a mild afternoon, have the system checked. On a dual-fuel system, where a gas furnace takes over from the heat pump in colder weather, either half can fail — and so can the control that switches between them.
Repair or Replace: The Furnace Math in North Texas
Age alone does not condemn a furnace. ENERGY STAR lists a furnace or boiler more than 15 years old as a sign to consider replacement, and says an ENERGY STAR qualified furnace is 15% more efficient than a conventional furnace. For this part of the country the numbers are modest: per ENERGY STAR, certified gas furnaces carrying its “U.S. South” label are up to 16 percent more efficient than standard models and can save an average of $60 in energy costs each year.
That is a program average for the southern half of the country, not a quote for your house. It does show why, in a climate with a short heating season, energy savings alone seldom pay for replacing a furnace that can be repaired safely. The decision usually turns on safety and reliability instead: a cracked heat exchanger, a furnace that needs repair after repair, or an air conditioner on the same system that is also near the end of its life. One more change since last year: the federal Energy Efficient Home Improvement Credit (Section 25C) applied only to improvements made through December 31, 2025, so a furnace installed after that date does not earn it.
Who Can Repair a Furnace in Texas
Heating repair is licensed work in Texas. The Texas Department of Licensing and Regulation (TDLR) states that contractors who install, repair, or maintain systems related to air conditioning, refrigeration, or heating must have a TDLR license. Before anyone opens your furnace, ask for the license number and look the company up by business name in TDLR’s public license search. Phanton Mechanical holds Texas Air Conditioning and Refrigeration Contractor License TACLA124868E, a Class A license issued by TDLR.
What a Furnace Repair Visit Covers
Our heating diagnostic is a flat $89. It covers the full system — ignition, burners, heat exchanger, venting, and safety controls on a gas furnace; refrigerant, defrost, and backup heat on a heat pump — and you get a written repair price before any work starts. Every furnace visit includes a heat-exchanger inspection and a check of the venting and gas connections, because a repair that gets the burners lit is not finished until the furnace is also venting correctly.
We carry the common parts — ignitors, flame sensors, inducer motors, gas valves, control boards — so most of these repairs are done the same day. We work on gas furnaces, heat pumps, and dual-fuel systems across Arlington, Pantego, and Dalworthington Gardens, and in Grand Prairie, Mansfield, and Fort Worth.
Sources: ENERGY STAR — Furnaces · ENERGY STAR — When Is It Time to Replace? · ENERGY STAR — Maintenance Checklist · U.S. DOE — Home Upgrades: Heat Pumps · National Weather Service Fort Worth — DFW Earliest and Latest Freezes · Atmos Energy — Recognizing a Natural Gas Leak · CDC — Carbon Monoxide Poisoning Basics · TDLR — Air Conditioning and Refrigeration Contractors · IRS — Energy Efficient Home Improvement Credit (Section 25C)
Quick Answers.
How much does furnace repair cost in Arlington?
It depends on which part failed, so the honest answer comes after the diagnosis, not before. Our diagnostic is a flat $89 and covers the whole heating system. You get the repair price in writing before any work starts, and you decide from there.
Why is my furnace running but blowing cold air?
Check the thermostat fan setting first: On runs the blower between heating cycles, so the air feels cold even when the furnace is fine. If the fan is on Auto, the usual causes are burners that never stay lit — a failed ignitor or a dirty flame sensor — or a clogged filter that overheats the furnace until the high-limit switch shuts the burners off while the blower keeps running.
Why does my furnace keep turning on and off?
Short-cycling usually means the furnace is protecting itself. A clogged filter or closed registers make it overheat and trip the high-limit switch; a dirty flame sensor makes it light and drop out within seconds. Change the filter and open the registers. If it keeps cycling, stop resetting it and have it diagnosed.
Is a 15-year-old furnace worth repairing?
Often, yes. ENERGY STAR lists more than 15 years as a sign to consider replacement, but its own figure for furnaces with the “U.S. South” label is an average of $60 a year in energy savings, so in North Texas the case for replacing rests on safety and reliability. A cracked heat exchanger or a pattern of repeat failures is a reason to replace; a failed ignitor is not.
Can I repair my own furnace?
The homeowner jobs are the filter, the thermostat settings and batteries, the furnace power switch, and one breaker reset. Gas connections, burners, and the heat exchanger are where a mistake becomes a gas leak or carbon monoxide, so leave those alone. Anyone you hire for the work must be licensed: TDLR requires a license for contractors who install, repair, or maintain heating systems.
Do you repair heat pumps and dual-fuel systems?
Yes. We diagnose and repair heat pumps and dual-fuel systems as well as gas furnaces: refrigerant, defrost controls, reversing valves, and backup heat on a heat pump, plus the gas furnace side of a dual-fuel system.